Influences of different reserved diopters during cataract extraction combined with TECNIS Symfony intraocular lens implantation on visual quality of presbyopia correction

Authors: Tan Jilin,  Qin Yan,  Wang Changpeng,  Ye Jian

DOI: 10.3760/cma.j.issn.2095-0160.2019.10.004
Published 2019-10-10
Cite as Chin J Exp Ophthalmol, 2019,37(10): 785-791.

Abstract                              [View PDF] [Read Full Text]

Objective

To compare the efficacy and visual quality of biocular cataract surgery combined with TECNIS Symfony intraocular lens(IOL) implantation in the correction of presbyopia with three different methods of reserved diopters.

Methods

A prospective cohort design was adopted.From October in 2016 to December in 2018, 120 patients 240 eyes with binocular cataract surgery implanted TECNIS Symfony IOL were divided into regular group, micro-near-vision group and micro-monovision group according to different reserved diopters, 40 patients 80 eyes in each group.The binocular IOL reserved diopter is + 0.10–0.20 D in regular group.The binocular IOL reserved diopter is -0.20–0.50 D in micro-near-vision group, meanwhile, the dominant eye reserved diopter is + 0.10–0.20 D, and the non-dominant eye reserved the myopia of -0.50–0.75 D in micro-monovision group.Defocus curves of single eye and binocular were measured and full distance visual acuity were analyzed 3 months after surgery.MTF values were detected by iTrace and compared between different groups.Visual function questionnaire of multifocal intraocular lenes (MIOLs)were analyzed and spectacle independence rate of presbyopia correction and disturbing photic phenomena were compared 3 months after surgery.This study protocol was approved by the ethics committee of Chongqing Aier Mega Eye Hospital, and this study followed the Declaration of Helsinki.

Results

Compared with regular group, the whole defocus curve of micro-near-vision group actually shifted to the right by 0.35 D, with almost no change in shape.The shape of the binocular defocus curve of micro-monovision group changed significantly compared with that of regular group, that is the wave peak became significantly wider, and the downward trend was more gentle.Spectacle independence rate of the three groups were all 100.00%, spectacle independence rate of intermediate distance in Micro-monovision group was 100.00%, which was higher than that of regular group(80.00%) and micro-near-vision group(90.00%), and the differences were statistically significant (χ2=37.04; P<0.01). The MTF value of the dominant eye was higher than that of the non-dominant eye in the Micro-monovision group, and the difference was statistically significant(t=3.74, P=0.001). There was no statistically significant difference in the occurrence rate of disturbing photic phenomena among the three groups(P>0.05).

Conclusions

Different reserved diopter design during cataract extraction combined with TECNIS Symfony IOL implantation suits different patients.Among the three different reserved diopters methods, the effect of micro-monovision method can obtain the highest spectacle independence rate, and provide satisfactory binocular far to near full-distance visual acuity.

Key words:

Cataract; TECNIS Symfony intraocular lens; Micro-monovision; Presbyopia correction

Contributor Information

Tan Jilin
Aier Mega Eye Hospital of Chongqing, Chongqing 400060, China
Qin Yan
Aier Mega Eye Hospital of Chongqing, Chongqing 400060, China
Wang Changpeng
Aier Mega Eye Hospital of Chongqing, Chongqing 400060, China
Ye Jian
Department of Ophthalmology, Army Medical Center of PLA(Daping Hospital, Army Medical University, Chongqing 400042, China
(Read 156 times, 1 visits today)
Updated: December 28, 2022 — 1:52 am