Category: Clinical Science

Repeatability of new Corvis ST parameters and influencing factors in myopia patients

Authors: Ren Shengwei,  Yang Kaili,  Xu Liyan,  Fan Qi,  Zhai Yaohua,  Pang Chenjiu DOI: 10.3760/cma.j.issn.2095-0160.2019.12.011 Published 2019-12-10 Cite as Chin J Exp Ophthalmol, 2019,37(12): 990-994. Abstract                               [View PDF] [Read Full Text] Objective To evaluate the repeatability of corneal biomechanics parameters measured by Corneal Visualization Scheimpflug Technology […]

Clinical evaluation for atropine penalization in treatment of moderate and severe anisometropic amblyopia

Authors: Zhao Kuiqing,  Yang Likun,  Li Ningdong DOI: 10.3760/cma.j.issn.2095-0160.2019.12.012 Published 2019-12-10 Cite as Chin J Exp Ophthalmol, 2019,37(12): 995-999. Abstract                               [View PDF] [Read Full Text] Objective To evaluate the effect of atropine penalization for treatment of moderate and severe anisometropic amblyopia. Methods Retrospective cohort study was […]

Efficacy of 25 gauge minimally invasive vitrectomy combined with cataract extraction and trabeculectomy surgeries for malignant glaucoma

Authors: Sun Chao,  Tan Chengye,  Wang Qingru,  Bao Xun,  Zhuang Miao,  Yao Yong DOI: 10.3760/cma.j.issn.2095-0160.2019.12.013 Published 2019-12-10 Cite as Chin J Exp Ophthalmol, 2019,37(12): 1000-1003. Abstract                              [View PDF] [Read Full Text] Objective To evaluate the efficacy and outcome of 25 gouge (25G) […]

Analysis of genotype and phenotype of hereditary retinal diseases which are easily misdiagnosed as amblyopia

Authors: Qi Rui,  Zhu Jinyan,  Wang Xiaoguang,  Zhuang Wenjuan,  Sheng Xunlun DOI: 10.3760/cma.j.issn.2095-0160.2019.11.008 Published 2019-11-10 Cite as Chin J Exp Ophthalmol, 2019,37(11): 888-895. Abstract                              [View PDF] [Read Full Text] Objective To analysis the genotype and phenotype of hereditary retinal diseases (HRD) which are easily misdiagnosed as […]

Genetic screening of the congenital aniridia and genotype-phenotype analysis

Authors: Li Jie,  Li Zhanrong,  Xing Yasi,  Peng Haiying,  Dai Shuzhen DOI: 10.3760/cma.j.issn.2095-0160.2019.11.009 Published 2019-11-10 Cite as Chin J Exp Ophthalmol, 2019,37(11): 896-900. Abstract                              [View PDF] [Read Full Text] Objective To explore the genotype-phenotype correlation among 3 pedigrees affected with congenital aniridia. Methods Clinical data and […]

Analysis of anterior chamber morphological changes after small incision lenticule extraction

Authors: Zhang Yaohua,  Wang Yan DOI: 10.3760/cma.j.issn.2095-0160.2019.11.010 Published 2019-11-10 Cite as Chin J Exp Ophthalmol, 2019,37(11): 901-906. Abstract                              [View PDF] [Read Full Text] Objective To investigate the changes of anterior chamber profiles after small incision lenticule extraction(SMILE) and analyze the possible influencing […]

The effect comparision of femtosecond laser-assisted phacoemusification and microincision phacoemusification on ocular surface

Authors: Xu Rong,  Zhao Shaozhen DOI: 10.3760/cma.j.issn.2095-0160.2019.11.011 Published 2019-11-10 Cite as Chin J Exp Ophthalmol, 2019,37(11): 907-913. Abstract                              [View PDF] [Read Full Text] Objective To compare the effects of femtosecond laser-assisted phacoemusification and microincision phacoemusification on ocular surface. Methods A nonrandomized comparative […]

Comparision of visual quality after topography-guided and wavefront-optimized FS-LASIK in myopic eyes

Authors: Zhang Li,  Zhai Changbin,  Zhou Yuehua,  Qi Ying,  Zhang Jing,  Zheng Yan,  Liu Qian DOI: 10.3760/cma.j.issn.2095-0160.2019.11.012 Published 2019-11-10 Cite as Chin J Exp Ophthalmol, 2019,37(11): 914-920. Abstract                              [View PDF] [Read Full Text] Objective To compare the visual quality after topography-guided customized […]

Repeatability and reproducibility of swept-source optical coherence tomography biometer for measuring the biological parameters of the eyeballs in healthy people

Authors: Liu Bo,  Liao Xuan,  Lan Changjun,  Peng Yue,  Tan Qingqing  DOI: 10.3760/cma.j.issn.2095-0160.2019.11.013 Published 2019-11-10 Cite as Chin J Exp Ophthalmol, 2019,37(11): 921-925. Abstract                              [View PDF] [Read Full Text] Objective To evaluate the repeatability and reproducibility of swept-source optical coherence tomography biometrics (Tomey OA-2000) for measuring […]

Influences of different reserved diopters during cataract extraction combined with TECNIS Symfony intraocular lens implantation on visual quality of presbyopia correction

Authors: Tan Jilin,  Qin Yan,  Wang Changpeng,  Ye Jian DOI: 10.3760/cma.j.issn.2095-0160.2019.10.004 Published 2019-10-10 Cite as Chin J Exp Ophthalmol, 2019,37(10): 785-791. Abstract                              [View PDF] [Read Full Text] Objective To compare the efficacy and visual quality of biocular cataract surgery combined with TECNIS Symfony intraocular lens(IOL) implantation in the correction […]