Evaluation of the effect of spectacle lens wear on exophthalmometry values in myopia using propensity score matching

Authors: Zhang Hongmei, Zhu Yun, Gao Fei, Jin Nan, Wei Ruihua
DOI: 10.3760/cma.j.cn115989-20230418-00139
   

Citation

Zhang Hongmei, Zhu Yun, Gao Fei, et al. Evaluation of the effect of spectacle lens wear on exophthalmometry values in myopia using propensity score matching[J]. Chin J Exp Ophthalmol, 2025, 43(6):542-547. DOI: 10.3760/cma.j.cn115989-20230418-00139.

[Download PDF] [View Full Text]

ABSTRACT

Objective  To investigate whether spectacle lens wear affects the exophthalmometry values (EVs) on myopia and explore the risk factors for EVs in myopia.

Methods  A cross-sectional study was conducted.A total of 935 university freshmen (935 eyes) who received eye examinations were enrolled from September to December 2019.Anterior segments were examined by slit lamp microscopy.EVs were measured with a Hertel exophthalmometer.Non-cycloplegia auto-refraction, lensometer test, visual acuity test and subjective refraction were performed on all subjects.Ocular biometric parameters including axial length (AL) and average corneal radius (CR) were obtained by Lenstar 900.A 1∶1 propensity score matching (PSM) was performed between the spectacle group and the non-spectacle group to compare the differences in EVs and visual acuity.Linear regression was used to analyze the effect of different factors on the EVs in all myopic students.This study adhered to the Declaration of Helsinki.The study protocol was approved by the Ethics Committee of Tianjin Medical University Eye Hospital (No.2021KY-16).Written informed consent was obtained from each subject.

Results  The mean EVs of students was (14.03±1.87)mm.There were significant differences in the distribution of myopia severity between the spectacle group and non-spectacle group before matching ( χ 2=345.800, P<0.001), and after PSM, the baseline characteristics of the two groups were well balanced with good comparability.After PSM, there was no significant difference in EVs between the spectacle group and non-spectacle group ([13.93±1.87]mm vs.[13.66±1.85]mm; t=1.140, P=0.25), and the spectacle group had better visual acuity of 1.0(0.8, 1.0) than 0.4(0.2, 0.8) in non-spectacle group, with a statistically significant difference ( Z=-8.450, P<0.001).Multivariate linear regression showed that EVs increased by 0.06 mm for every 1 D increase in spherical equivalent towards myopia ( β=-0.06, 95% CI: -0.11–0.01, P=0.03), and EVs increased by 0.17 mm for every 1 mm increase in AL ( β=0.17, 95% CI: 0.06-0.28, P<0.01).Average CR did not influence EVs significantly ( β=0.07, 95% CI: -0.10-0.24, P=0.43).

Conclusions  Wearing spectacles may not affect the EVs and not wearing spectacle may affect visual acuity in myopic patients.The higher the degree of myopia, the longer the AL, the higher the EVs may be.

Myopia;Exophthalmometry values;Spherical equivalent;Axial length

Authors Info & Affiliations 

Zhang Hongmei
Tianjin Medical University Eye Hospital, Tianjin 300384, China
Zhu Yun
School of Public Health, Tianjin Medical University, Tianjin 300070, China
Gao Fei
Tianjin Medical University Eye Hospital, Tianjin 300384, China
Jin Nan
Tianjin Medical University Eye Hospital, Tianjin 300384, China
Wei Ruihua
Tianjin Medical University Eye Hospital, Tianjin 300384, China
(Read 12 times, 1 visits today)