Tag: Diagnostic techniques

Advances in optical coherence elastography in ophthalmology

Authors: Zhao Yanzhi,  Huang Guofu DOI: 10.3760/cma.j.cn115989-20221116-00533 Published 2023-10-10 Cite as Chin J Exp Ophthalmol, 2023, 41(10): 1043-1048. Abstract                             【Download PDF】 【Read Full Text】 Optical coherence elastography (OCE) is a novel technique developed in recent years to investigate the biomechanical properties of tissues, […]

Review on the detection of tear pathogen and immune component and its clinical significance

Authors: Gao Qi,  Tao Yong DOI: 10.3760/cma.j.cn115989-20190830-00375 Published 2021-02-10 Cite as Chin J Exp Ophthalmol, 2021,39(02): 154-160. Abstract                              [View PDF] [Read Full Text] Ocular surface diseases are common diseases in ophthalmology.It is difficult for clinicians to make early and accurate diagnosis […]

Influence of watching video display terminal on ocular surface and application of non-invasive ocular surface analyzer

Authors: Xiong Chan,  Liu Zhenkai,  Ji Kaibao,  Yu Li,  Gu Xuejun,  Zhang Xu DOI: 10.3760/cma.j.issn.2095-0160.2016.05.012 Published 2016-05-10 Cite as Chin J Exp Ophthalmol, 2016,34(5): 443-447. Abstract                              [Download PDF] [Read Full Text] Background The incidence of dry eye is increasing among young adults because of wide usage […]

Change in corneal biomechanical properties and influence factors in population with myopia

Authors: Deng Zhengzheng,  Li Shiming,  Zhou Yuehua,  Zhang Jing DOI: 10.3760/cma.j.issn.2095-0160.2016.09.014 Published 2016-09-10 Cite as Chin J Exp Ophthalmol, 2016,34(9): 842-846. Abstract                              [Download PDF] [Read Full Text] Background Corneal refractive surgery has significant effects on corneal biomechanical properties.However, there are few study on large scale […]

The accuracy of ultrasonography in 5 500 mPas silicone-tamponade eyes

Authors: Sun Qiongqiong,  Liu Guojun,  Zang Xinjie,  Wang Xiuping DOI: 10.3760/cma.j.issn.2095-0160.2016.09.009 Published 2016-09-10 Cite as Chin J Exp Ophthalmol, 2016,34(9): 813-817. Abstract                               [Download PDF] [Read Full Text] Background The ultrasonography for silicone tamponade eye is a problem in diagnosis and treatment of eye diseases, especially for the calculation of […]

The morphologic and quantitative evaluation of ocular anterior chamber parameters after laser peripheral iridotomy in primary angle-closure glaucoma eyes

Authors: Liu Xiaoli,  Liu Danyan,  Zhang Bin,  Guo Congrong,  Du Yinghua,  Duan Jialiang DOI: 10.3760/cma.j.issn.2095-0160.2016.07.008 Published 2016-07-10 Cite as Chin J Exp Ophthalmol, 2016,34(7): 608-612. Abstract                              [Download PDF] [Read Full Text] Background Pentacam anterior segment analysis system(Pentacam) is more accurate in the quantitative evaluation of ocular […]

Agreement in optic disc measurements between Cirrus HD-OCT and Heidelberg retinal tomograph Ⅱ in myopic eyes

Authors: Qiu Kunliang,  Zhang Riping,  Wang Geng,  Lu Xuehui,  Zhang Mingzhi DOI: 10.3760/cma.j.issn.2095-0160.2016.08.017 Published 2016-08-10 Cite as Chin J Exp Ophthalmol, 2016,34(8): 744-749. Abstract                              [Download PDF] [Read Full Text] Background As myopia is a common ocular condition which has been reported as the risk factor of […]

Morphology changes of ocular anterior segment and its influencing factors following LASIK

Authors:Wang Jie,  Du Zhiyu,  Li Xueyao,  Zhang Yu,  Yan Pisong,  Chen Huizhen,  Yao Hao DOI: 10.3760/cma.j.issn.2095-0160.2016.08.014 Published 2016-08-10 Cite as Chin J Exp Ophthalmol, 2016,34(8): 729-733. Abstract                            [Download PDF] [Read Full Text] Background Laser in situ keratomileusis (LASIK) is widely applicated to correct the refractive error in […]

Repeatability of Ophtha TOP in measuring corneal parameters and its agreement with Pentacam

Authors:Yu Shasha,  Song Hui,  Tang Xin DOI: 10.3760/cma.j.issn.2095-0160.2016.12.014 Published 2016-12-10 Cite as Chin J Exp Ophthalmol, 2016,34(12): 1116-1120. Abstract                              [Download PDF] [Read Full Text] Background Accurate measurement of corneal refractive parameters plays an important role in the diagnosis of eye diseases, design of refractive surgery and calculation of intraocular lens […]

Analysis of meibomain gland change and ocular surface condition in age-related cataract population

Authors: Yu Hua,  Li Bing,  Wang Jingjing DOI: 10.3760/cma.j.issn.2095-0160.2017.09.014 Published 2017-09-10 Cite as Chin J Exp Ophthalmol, 2017,35(9): 838-842. Abstract                              [Download PDF] [Read Full Text] Background Meibomain gland is a specially differentiated sebaceous gland lying in the tarsus of upper and lower eyelid.The morphological changes of the gland […]