Authors: Shen Di, Zhang Na, Sun Xiyu, Wei Wei DOI: 10.3760/cma.j.cn115989-20260121-00038 Published: 2026 -05 -10 Citation Shen Di, Zhang Na, Sun Xiyu, et al . In vitro study on corneal biomechanical changes after corneal stromal lenticule implantation combined with corneal collagen cross-linking[J]. Chin J Exp Ophthalmol, 2026, 44(5):439-446. DOI: 10.3760/cma.j.cn115989-20260121-00038. ABSTRACT […]
Tag: Corneal biomechanics
Efficacy and safety of refractive surgery combined with prophylactic collagen cross-linking for ametropia
Authors: Mo Fei, Li Ying DOI: 10.3760/cma.j.cn115989-20220624-00295 Published 2024-04-10 Cite as Chin J Exp Ophthalmol, 2024, 42(4): 376-385. Abstract 【Download PDF】 【Read Full Text】 Corneal refractive surgery is a safe and effective way to correct ametropia.Although the biomechanical stability of the cornea is reduced […]
Comparison of corneal biomechanics in the early postoperative period between TransPRK and SMILE
Authors: Ning Jiliang, Fang Shifeng, Jin Lin, Yan Chunxiao, Sun Siyu, Chen Ruoyu, Xing Zequn, Yu Taorui, Zhang Lijun DOI: 10.3760/cma.j.cn115989-20211130-00659 Published 2023-11-10 Cite as Chin J Exp Ophthalmol, 2023, 41(11): 1098-1104. Abstract 【Download PDF】 【Read Full Text】 Objective To investigate the effects […]
Evaluation of the sensitivity and specificity of corneal visualization scheimpflug technology biomechanical index in the diagnosis of keratoconus
Authors:Zhai Yaohua, Pang Chenjiu, Ren Shengwei, Dai Lijuan, Fan Qi DOI: 10.3760/cma.j.issn.2095-0160.2019.07.007 Published 2019-07-10 Cite as Chin J Exp Ophthalmol, 2019,37(7): 527-531. Abstract [View PDF] [Read Full Text] Objective To study the sensitivity and specificity of parameter Corvis biomechanical index (CBI)— a new biomechanical index of […]
Association between corneal volume change and corneal biomechanical property before and after small incision lenticule extraction in myopia
Authors: Wei Pinghui, Wang Yan, Li Hua, Dou Rui, Zhang Jiamei, Zhao Wei, Li Liuyang DOI: 10.3760/cma.j.issn.2095-0160.2017.02.011 Published 2017-02-10 Cite as Chin J Exp Ophthalmol, 2017,35(2): 146-150. Abstract [Download PDF] [Read Full Text] Background The relationship between corneal central thickness (CCT) and corneal biomechanical property does not reflect the effective amount of […]
Change of corneal biomechanical properties caused by phacoemulsification using corneal visualization Scheimpflug technology
Authors: Xu Lingxiao, Wei Yinjuan, Song Hui DOI: 10.3760/cma.j.issn.2095-0160.2018.02.013 Published 2018-02-10 Cite as Chin J Exp Ophthalmol, 2018,36(2): 140-143. Abstract [Download PDF] [Read Full Text] Objective To explore the corneal biomechanical characteristics change in cataractous eyes before and after phacoemulsification using corneal visualization Scheimpflug technology (Corvis ST) and […]
Research of diagnostic value of corneal biomechanical parameters based on Corvis ST in keratoconus
Authors: Wu Yuan, Li Xiaoli, Yan Xiaoming, Rong Bei, Li Haili DOI: 10.3760/cma.j.issn.2095-0160.2018.02.011 Published 2018-02-10 Cite as Chin J Exp Ophthalmol, 2018,36(2): 130-134. Abstract [Download PDF] [Read Full Text] Objective To compare the corneal biomechanical properties between keratoconic eyes and normal eyes by using corneal visualization Scheimpflug technology (Corvis ST), […]
Allogeneic corneal small incision intrastromal lenticule inlays for moderate and high hyperopia: one year follow-up
Authors: Zhang Jing, Zhai Changbin, Zheng Yan, Liu Qian, Wang Yue, Song Xiumei, Zhang Qiulu, Hu Yabin, Zhou Yuehua DOI: 10.3760/cma.j.issn.2095-0160.2018.05.007 Published 2018-05-10 Cite as Chin J Exp Ophthalmol, 2018,36(5): 355-359. Abstract [Download PDF] [Read Full Text] Objective This study was to evaluate the long-term clinical efficiency of allogeneic corneal intrastromal lenticule inlay for […]
Evaluation of corneal biomechanical properties modification following intrastromal correction of presbyopia using femtosecond laser
Authors: Ji Peng, Bi Hongsheng, Fan Hua, Hu Bing, Liu Cuihong, Zhang Daixing, Wang Xinrong DOI: 10.3760/cma.j.issn.2095-0160.2019.02.007 Published 2019-02-10 Cite as Chin J Exp Ophthalmol, 2019,37(2): 106-110. Abstract [Download PDF] [Read Full Text] Objective To investigate the changes of corneal biomechanics of intrastromal correction (INTRACOR) femtosecond technique to […]